RBT-PMB-85P

8 Channel 24V 5A Mosfet Board Open Push-In terminal block

SKU:

mosfet-karti

Introduction and Features: EN

This circuit board is specially designed as an alternative to relays in automation systems. Hydraulic and pneumatic valves are faster switches and have a much longer life than relays. It also takes up less space in your panel because it has a compact design.

This product works with 24V and you can control loads that operate with 24V. This 8-channel product can deliver a continuous current of 5A per channel. A maximum current of 20A can be drawn from the board at the same time.

Advantages:

·       Easy to install in the panel.

·       Powerful cooling

·       Withstands instantaneous 10A high currents for up to 3 seconds.

·       Switch-on time less than 15us and switch-off time less than 150us.

·       No arcing, long life.

·       Input signal is optically isolated.

·       N-channel or P-channel selection of the input signal is selected with a slide switch.

·       7+1 feature: When any of the channels 1,2,3,4,5,6,7 are active, channel 8 is also active. This feature is used in hydraulic systems.

·       The 7+1 feature is also selected with a slide switch.

·       Powerful cooling: It is inevitable that mosfets get hot while working. That's why the card's performance is optimized with a powerful heatsink.

Features:

·       24V operation.

·       Support voltage drop up to 20V.

·       8 channels of independently controllable input and output.

·       5A continuous current per channel.

·       LED indicating that the channels are active.

·       Easy installation with push-in terminals.

·       Rail mounting box.

Application Areas:

·       Automation systems

·       Industrial applications

·       It can be used safely in almost all systems operating with DC 24V.

Port Introduction

Symbol

Port Definitions

V --

GND

+24V

+24V power supply

IN1-IN8

Input ports

OUT1-OUT8

output ports

Electrical Characteristic

Ports

Value

Tolerance

Unit

V--

0

-

V

+24V

+24

±3

V

IN1-IN8

+24/0

V

OUT1-OUT8

+24/0

V

Continuous current per channel T=25˚C

5

5

A.

Using DIP SWITCH

In order to select the card's input signal as P channel or N channel, adjustment must be made with the slide switch . The factory setting for input signal type is P channel. To set the input signal as N-channel, the P-channel pin on the slide switch must be pulled to “OFF” and then the N-channel pin must be pulled to “ON”. For 7+1 used in hydraulic systems, the 7+1 channel must be set to “ON”. 7+1 feature is set to “OFF” in factory settings.

Time Values

Time

Value

Tolerance

Unit

10

±5

µs

130

±20

µs

 

Product sizes

A rail mount card holder was used to mount the card to the panel.

External dimensions of the card:

Height: 48mm

Width: 546mm

Length: 76mm